Let's talk. Let's invent. Let's make it happen.
Order status 0
Code HRR2

Injector and IAC Valve Tester

1 / 16

Fuel-injected engines built between 1990 and 2008 usually have a valve that regulates idle speed. That valve is called the IAC (Idle Air Control), commonly known as a stepper motor.
This valve is a frequent cause of failures.

Indirect-injection engines use coil-based injectors, split into two main groups: high and low impedance.
This device can test almost all IAC valves and stepper motors used in the automotive industry, and both groups of injectors.

It's the easiest tester to use on the market.

Built for heavy-duty use, with high durability.
The device tests multiple IAC types (stepper, PWM, DC current, etc.)
It's an essential tool for any modern mechanic and advanced users.
Auto-open paused.


-Autodetection: just plug in the IAC or injector, wait 1 second, and testing begins (it can't get any easier)
-Tests stepper motors
-Tests single-coil PWM IACs
-Tests double-coil PWM IACs
-Tests DC motor IACs
-Magnetti Marelli, Bosch, and all compatible equivalents
-Slow motion for fine adjustment in fixed mode
-Fast motion to verify smooth movement
-3 different injection pulse times (2ms, 4ms and 6ms) at 4000 RPM
-Flow test using a 4ms pulse at 4000 RPM for 1 minute
-Sequential injector firing to keep the pressure in the rail constant
-Short-circuit and overload detection
-Tests up to 4 high/low-impedance injectors simultaneously
-Interchangeable connectors for all car types
-Economical, robust, and easy to use





Testing a Magnetti Marelli stepper motor is very easy.

1)Connect the HRR2 and wait for the lights to blink.
2)Plug in the stepper motor and wait one second.
3)READY! It's that easy — the MM led turns on.

4)The right and left buttons open and close the motor.
5)Pressing both side buttons at the same time starts an automatic open/close cycle.

This motor is a double-step, double-coil stepper motor with polarity reversal.

Testing a General Motors stepper motor is very easy.

1)Connect the HRR2 and wait for the lights to blink.
2)Plug in the stepper motor and wait one second.
3)READY! It's that easy — the GM led turns on.
4)The right and left buttons open and close the motor.
5)Pressing both side buttons at the same time starts an automatic open/close cycle.

This motor is a double-step, double-coil stepper motor with polarity reversal.


Testing a Rover stepper motor is very easy.

1)Connect the HRR2 and wait for the lights to blink.
2)Plug in the stepper motor and wait one second.
3)READY! It's that easy — the 5W led turns on.

4)The right and left buttons open and close the motor.
5)Pressing both side buttons at the same time starts an automatic open/close cycle.

This motor is a single-step, four-coil stepper motor with a common supply and no polarity reversal.

Testing a 2-way IAC valve is very easy.

1)Connect the HRR2 and wait for the lights to blink.
2)Plug in the valve and wait one second.
3)READY! It's that easy — the IAC led turns on.

4)The right and left buttons open and close the valve.
5)Pressing both side buttons at the same time starts an automatic open/close cycle.

This valve type has a displacement proportional to the duty cycle applied over a single coil.

Testing a 3-way IAC valve is very easy.

1)Connect the HRR2 and wait for the lights to blink.
2)Plug in the valve and wait one second.
3)READY! It's that easy — the 3W led turns on.

4)The right and left buttons open and close the motor.
5)Pressing both side buttons at the same time starts an automatic open/close cycle.

This valve type has two coils: a displacement proportional to the duty cycle is applied over one of them, while the other applies an opposing force.

Testing a DC motor IAC valve is very easy.

1)Connect the HRR2 and wait for the lights to blink.
2)Plug in the motor and wait one second.
3)READY! It's that easy — the CC led turns on.

4)The right and left buttons open and close the motor.

This valve type uses a single common DC motor that, through a gear set, achieves smooth movement.

When testing injectors, keep in mind that the HRR2 has 2 test types (Continuous and Timed).
In both tests, up to 4 injectors can be tested at the same time; the tests run in sequential mode at 4000 RPM.
Sequential means only one injector opens at a time, which keeps the pressure in the rail stable.

To test more than one injector, simply connect them and you're done (up to 4 injectors).
If you only want to test one injector, after plugging it in you must press the middle button once.


Continuous test
Plug in the injectors; each time you press the left button, the injectors' opening time changes following this sequence:

image

If at least ONE low-impedance injector is connected, only the 2ms opening will work.

The injectors keep running continuously until, with the left button, you reach the STOP position, or you press the right button, press the middle button, or disconnect the HRR2.

This test is usually used to clean the injectors.

Timed test
Plug in the injectors; when you press the right button, a 4ms test will start and run for 1 minute.
If at least ONE low-impedance injector is connected, the opening time will only be 2ms.
This lets you check that the flow rate is the same across all injectors.


Maximum Voltage
25V
Nominal Voltage
12Vdc
Working voltage
9~16Vdc
Working Temperature
5°c ~ 45°c (41°f~113°f)
Double-step stepper
Autodetected (Magnetti Marelli, General Motors)
Single-step stepper
Autodetected (Rover, Mitsubishi)
IAC PWM
600Hz with variable duty cycle.
Max consumption of steppers
750mA
Max consumption of IAC valves
800mA
Max consumption of injectors
2A
Short-circuit protection
Current sensing with an automatically resettable fuse (there is no perfect protection, do not create a short circuit)
Short-circuit detection
Yes, all leds blink together
Open-fuse detection
Yes, the LEDs turn on one by one moving from right to left
Leds
7 ( MM/GM/3W/CC/5W/IAC/Iny)
Enclosure
Injected recyclable ABS plastic
Measures
135mm x 75mm x 24mm ( 53.1 in x 29.5 in x 9.4 in )


Your purchase includes:

1 HRR2
1 User Manual
1 Included Cable


Included Cable
image

4 x 2-way for injectors and IAC
1 x 4-way for stepper motors


Extra Cable 1
image

1 x 3-way for IAC PWM Bosch
1 x 4-way for CC-type IAC Bosch
1 x 2-way for some Fiat injectors
1 x 2-way for Nippon Denso injectors (Hyundai)


Extra Cable 2
image

1 x 6-way for Rover
1 x 4-way for old GM

You can download the user manual from the following links:



If you want to buy, you will always get the most recent version. If you already have a device and want to know which version you have, look at the buttons area and compare it with the photos
image
Rev F. 101.07
image
Rev E. 101.06
image
Rev E. 101.05
image
Rev D. 101.04
image
Rev C. 101.03
image
Rev C. 101.02
image
Rev B. 101.01
image
HRR1. 101.00



0101.07
-[FEATURE]PCB Revision F
-[FEATURE]Rover-type IAC added with autodetection
0101.06
-Added manual selection of test
-Updated threshold level for low-impedance injectors
-Added double-coil PWM IAC (Renault 21 and VW Golf)
-Added service mode
-Slowed down stepper movement
-Fixed LEDs when only one injector is connected
-Slowed down PWM IAC displacement even further
0101.05
-Revision E
-Low-impedance injectors up to 2ms
-New way to control outputs
-Fuse opening is now marked as KITT
0101.04
-Revision D
-DC Motor
-4 low-impedance injectors
0101.03
-[BUG FIX]Avoided false detection of stepper with 4 low-impedance injectors.
-[BUG FIX]False short-circuit detection with 3 injectors
0101.02
-[FEATURE]Revision C SMT technology.
-[FEATURE]Raised up to 2.5A for each output, works up to 1 low-impedance injector in direct mode.
0101.01
-[FEATURE]Raised current up to 0.8A for 2 or more injectors before a short-circuit error.
-[FEATURE] Added 2-way IAC like Ford
-[FEATURE] Continuous run for stepper motors

0101.00

All mentioned trademarks are property of their respective owners. They are mentioned for reference only.