Let's talk. Let's invent. Let's make it happen.
Order status 0
Code TAU2

Complete Engine Protector for Cars, 2 Temperatures, Oil, Voltage w/Alarm and Shutdown

1 / 7

This device is essential to help save the engine's life.
Overheating is the most frequent cause of engine damage.
The red warning light or the original gauge usually warns too weakly and too late.

Knowing how important temperature control is, this device measures 2 temperatures simultaneously.
It reads coolant temperature, and if a leak occurs, a second sensor in the cylinder head takes over automatically.
It also monitors oil pressure and charging voltage, to warn the driver and help save the engine.

As easy to install as connecting 12v, ground, and the probe.
Economic, small and efficient.

Auto-open paused.

The TAU2-plus measure permanently and simultaneously 5 parameters: 2 temperatures, the charging voltage, radiator fan, presence of Oil pressure from original bulb (on/off).
For display reason it only one parameter at a time. With the up and down button you can change the displayed data in the following order.

T 1
Cylinder cover temperature
C° o F°
T 2
Coolant temperature
C° o F°
OIL
Oil pressure existence
0=without, 1=With pressure
VOL
Charging voltage
Volt


The engine temperatures is shown in a range from 0°c ~ 140°c (32°f~284°f).
When at least one temperature is greater than the critical value set by the user, or the voltage is out of the operating range, or oil pressure fails (for more than 15 seconds), the alarm starts. The screen shows the reason (T1, T2, Oil, Volt), the digits blink and a sound starts (one beep for each additional degree). This way, the alarm becomes more annoying as the overheating gets worse.
Pressing the middle button mutes the sound. It stays muted until the parameters return to normal.
When the temperature exceeds the critical temperature by 6 degrees, or the voltage or oil fails, the red LED turns on and the shutdown signal is sent. The shutdown signal is immediate from the factory, but you can configure a delay of up to 64 seconds. If driver mode is disabled, the middle button lets you continue driving.
If a fault condition is detected when you start the engine, the alarm and shutdown will not activate until the situation returns to normal.
When the radiator fan turn on, the blue LED will turn on, but no alarm will be generated.


The electric installation is easy, only you must follow the diagram:
image
Fan connection
Measure the voltage at both fan terminals, and write down the values on paper while the fan is off.
Turn on the engine, wait for the fan to turn on, and write down the new values.
Compare your readings with the following tables to see which one matches.
Example 1:
Fan OFF
Fan ON
Cable1
12v
12v
Cable2
12v
<6V

If your readings match example 1, connect the yellow cable to cable 2.

Example 2:
Fan OFF
Fan ON
Cable1
0v
0V
Cable2
0v
>6V

If your readings match example 2, connect the yellow cable to cable 2.

Oil bulb connection
The device measures the voltage present at the engine's original oil pressure bulb and shares that same connection — you don't need to remove or change anything. When the voltage on the orange cable is below 5V, the device understands there is no oil pressure and will trigger the alarm and shutdown. For this alert to work, the engine needs to have had oil pressure at some point.
image

Relay connection
You can optionally install a shutdown for the engine. There are many ways to stop an engine; the installer must be careful to choose a method that ensures:

-The driver doesn't lose the brakes.
-The driver doesn't lose steering.
-The driver doesn't lose control of the vehicle.


One viable option is to cut the fuel supply.


The second temperature is the coolant temperature. This is a separate connection from the original coolant sensor. Setting up the sensor can be divided into 3 stages: Choosing the type, Hydraulic, and Electric.

Sensor choosing
The first step is to choose the appropriate sensor; you need to use one of the following:
Code
Comments
NTCsch Probe
(same as head cup probe), the install instruction are similar to the probe 1 ( head cup) but in a pipe.
Calorstat VW2589 o Geny 22202
Used in the followings cars Siena 2004i 94~97, Astra 93~2001, Renault Fuego, VW gol >2005, Meriva, Citröen Jumper 99~2001, and many other cars.
RoyalTek RT2682
Used in Siena, Alfa romeo 146/148/166, Citroën Jumper 2.3Hd, Fiat Bravo 1.9Td, Ducato 1.9td/2.3/2.8, Marea 1.9td, Tempra 1.8/2.0 /tipo 1.6/2.0 / palio 1.2/1.7td /siena 1.2


B) If you chose the external contact probe SCHNTC, the installation, thermal isolation, and fixing instructions are similar to the cylinder cover probe.

Hydraulic
The sensor must be placed where coolant always flows. Generally, the original location is well calculated to read a good temperature.
Please note that the thermostat blocks coolant flow to the radiator, and a misplaced probe can read cooler than the real temperature. Also keep in mind that temperature is not uniform across the whole engine; depending on the spot, readings can differ by up to 25 degrees.

There Are 2 ways to install the sensor:
1) Add a hole and make the thread to place the sensor (better)
2) Add a TEE where is the original car sensor(simpler)

Electric
Connect the Violet wire in the B therminal and the A to the ground.

image



If the sensor is well placed, this is the best way to save the engine. However, it depends a lot on where the probe is installed, since it works by external contact.
This means that if the probe is poorly placed, the measurement will be wrong and you won't get any protection.
-The most warm place is in the gasket between block and head cup.
-The probe must have the max touch with the hot zone
-You need a thermal isolation with extern air
-The probe is made of glass, do not put pressure on it, do not hit it, or twist it
-DO NOT remove any original sensor of car.
-Avoid that the sensor be cooled by wind.
-The exhaust can affect the measure.
-Do not remove the Head Cup screws, they have a special torque.

image
C=Thermal isolaor ( Rubber, styrofoam, eva rubber)
B=Probe
A=Head Cup (cylinder cover)

Practical Tips
A) Sometimes there are unused holes originally made for screws; some customers put the sensor in the hole and sealed it from behind.
B) Another way is to use that hole to fit a screw and fix a plate that presses down on the eva rubber and the sensor.
C) If you can't find an unused hole, you can loosen an existing one to fit the plate, then put it back.
D) Glue. Glue can work well, but keep in mind that most glues lose strength at 100°C (212°F), and it's not good if the sensor comes loose at the most critical moment.
Also keep in mind that while the glue cures, the probe can shift away from the cylinder cover and lose thermal transfer.
E) Some people drill a hole; this should only be done by someone who knows the cylinder cover on both sides and is willing to take the risk involved.

Login
You enter setup mode by pressing the middle button for 3 seconds.
The screen will show: SET-XX, where XX is the product version.
Use the up and down buttons to choose the option you want and press the middle button. Change the value with the up and down buttons. When finished, press the middle button again.

Cr1
Critical Temperature 1
Choose this temperature keeping in mind that the alarm starts once this number is exceeded, and the shutdown happens 6 degrees above this number.
Cr2
Critical Temperature 2
Choose this temperature keeping in mind that the alarm starts once this number is exceeded, and the shutdown happens 6 degrees above this number.
VMI
Minimum Voltage
Choose the threshold voltage below which the alarm is triggered.
VMA
Maximum Voltage
Choose the threshold voltage above which the alarm is triggered.
FAN
Engine Fan
0=With the fan off there are 12v on the wire
1=With the fan off there are 0V on the wire
C-F
Degrees
0=Centigrade degrees
1=Fahrenheit degrees
BrI
Brightness
Adjusts the screen brightness
DLY
Delay
Is the time in seconds between the shutdown condition and the actual shutdown.
DRV
Driver
1= Forces the driver to wait for the engine to cool down before being able to continue driving. (It is recommended to activate a delay that allows the driver to pull over)
GPS
GPS
(only on models with this signal) Selects which temperature will be sent to the GPS tracking system.
EnD
END
Store the changes and end the setup menu.



You can download the user manual that apply to your model in the followings links




It is important to understand that the location of the probe is critical at the time of accurate measurement.
It is the user's full responsibility to choose a place that allows the best and most accurate measurement.
Likewise, it is the user's responsibility to choose a critical temperature according to their motor to avoid damage to it.

12v Version
Maximum Voltage
16V
Nominal Voltage
12Vdc
work Voltage
8~16Vdc


24v Version
Maximum Voltage
33V
Nominal Voltage
24Vdc
Work Voltage
8~33Vdc


Version GPS
Temperature out
Analog
Formula
Centigrade = Voltage_in*30.


All
Energy Consumption
0.21 A max
Temperature range
0°c ~ 140°c (32°f~284°f)
Measurement step
1°c (1.8°f)
Measurement unit
Centigrade grade and Fahrenheit grade
Maximum current output for relay
1A
Critical temperature
Regulable between 70°c ~ 140°c (158°f~284°f)
Probe type
NTC, pasive
Box
Recyclable ABS plastic, injection molded
Front
Transparent polycarbonate
Sizes
28mm x 47mm x 79mm ( 11 in x 18.5 in x 31.1 in )
Lifetime estimated
40 years



0811.06
-[feature] Delayed shutdown
-[feature] Driver mode
-[bug fix] Calibrations removed from the hands of the users


0811.05
-[feature] TAU2+ born as a separate project

u$s 53TAU2